UL2938

UL2938

• Conductor : 440 AWG min, solid or stranded round, tinned or bare copper.
• lnsulation : PVC Insulation and Jacket.
• Insulatior : 500VAC/min.

Inquiry
Please refer to the "Inquiry List" on Contact Us.

Summary

• Temperature : 90°C.
• Rated voltage : 30Volts.
• Passed UL VW-1 & CSA FT1 vertical flame test.
• Internal wiring of electronic equipment and appliances. Tags may indicate the following: "600 volts Peak for Electronic use only".

UL2938      
Wire Size Conductor ​Core Insulation Jacket Overall 
Construction Resistance Thickness Thickness Diameter
AWG No./mm Ω/km mm mm mm
30 7/0.10 354 2 0.38 0.38 3.2
3 3.4
4 3.7
28 7/0.127 223 2 0.38 0.38 3.4
3 3.6
4 3.95
26 7/0.16 140 2 0.38 0.38 3.6
3 3.8
4 4.2
24 11/0.16 87.6 2 0.38 0.38 3.8
3 4.1
4 4.4
22 17/0.16 55.4 2 0.38 0.38 4.2
3 4.5
4 4.9
20 26/0.16 34.6 2 0.38 0.38 4.5
3 4.8
4 5.3
18 41/0.16 21.8 2 0.38 0.38 5
3 5.35
4 5.85
16 65/0.16 13.7 2 0.38 0.38 5.6
3 6
4 6.6
14 41/0.251 8.62 2 0.38 0.38 6.4
3 6.85
4 7.55
12 65/0.251 5.43 2 0.38 0.38 7.3
3 7.8
4 8.65
10 105/0.251 3.409 2 0.38 0.38 8.6
3 9.2
4 10.2