UL2662

UL2662

• Conductor : 33-10 AWG solid or stranded round, tinned or bare copper.
• lnsulation : PVC Insulation and Jacket.
• Insulatior : 2000VAC/min.

Inquiry
Please refer to the "Inquiry List" on Contact Us.

Summary

• Temperature : 105°C.
• Rated voltage : 600Volts.
• Passes UL VW-1 & CSA FT1 vertical flame test.
• External interconnection of electronic equipment.

UL2662      
Wire Size Conductor ​Core Insulation Jacket Overall 
Construction Resistance Thickness Thickness Diameter
AWG No./mm Ω/km mm mm mm
30 7/0.10 354 2 0.76 1.52 7.1
3 7.4
4 7.95
28 7/0.127 223 2 0.76 1.52 7.2
3 7.55
4 8.1
26 7/0.16 140 2 0.76 1.52 7.4
3 7.75
4 8.3
24 11/0.16 87.6 2 0.76 1.52 7.6
3 7.95
4 8.55
22 17/0.16 55.4 2 0.76 1.52 7.9
3 8.3
4 8.9
20 26/0.16 34.6 2 0.76 1.52 8.1
3 8.5
4 9.15
18 41/0.16 21.8 2 0.76 1.52 8.8
3 9.25
4 10
16 65/0.16 13.7 2 0.76 1.52 9.4
3 9.9
4 10.7