UL1330

UL1330

• Conductor : Tinned Copper/ Silver Plated Copper.
• lnsulation : FEP Teflon.

Inquiry
Please refer to the "Inquiry List" on Contact Us.

Summary

• Temperature : -60°C~+200°C.
• Rated voltage : 600Volts.
• UL1330 FEP Teflon Wire is suitable for fields that require high temperature endurance. Application ranges from household appliances, lighting devices, to industrial machines, and high-temperature furnaces.

UL1330     
Wire Size Conductor Insulation Max Current
Construction Resistance Thickness O.D
AWG No./mm Ω/km mm mm Amp
28 0.12 x 7 223 0.51 1.39 1
26 0.16 x 7 152 0.51 1.52 1.5
24 0.12 x 19 88.6 0.51 1.62 2
22 0.16 x 19 62.5 0.51 1.78 3
20 0.19 x 19 39.5 0.51 1.98 5
18 0.235 x 19 24.4 0.51 2.2 8
16 0.3 x 19 15.6 0.51 2.53 11
14 0.37 x 19 9.8 0.51 2.83 15
12 0.45 x 19 5.21 0.51 3.39 21
10 0.6 x 19 3.27 0.51 4.04 29
8 0.75 x 19 2.06 0.76 5.3 35